WE Report

Lessons Learned

Lesson Learned





By: Drilling Supervisor

Report No.

2409

Discipline/Origin

Drilling
Own Experience

Well

Hemispheres
36/1-4

Date created

2022/01/01
1436 days ago

Project Phase

Operational
Project Phase

LL Type/Classification

Equipment
Other

Borgland Dolphin


What happened in Top hole:
When making up 18 3/4″ WHH to No Cross joint it was very tight clearance for upper and lower jaws to grip on pipe and not on the extended box on the No Cross joint.

What Was Planned

Used 1 3 3/8″ No Cross joint in casing string as last joint before making up 18 3/4″ WHH.

What Was Learned

The length of the box on the No Cross joint must be shorter than the distance between upper and lower jaws on the casing tong.

What Actions Are Required

Supplier of casing running equipment should check/ confirm distance between upper and lower jaws is longer than the box length on the No Cross joint.

What Was Done

Made up connection as planned but with very tight clearance for upper and lower jaws to grip on pipe and not on the extended box on the No Cross joint.